Sign In | Join Free | My tjskl.org.cn
China Aolittel Technology Co.,Ltd logo
Aolittel Technology Co.,Ltd
Professional manufacturer of fuse and fuse holder,on-time delivery
Site Member

8 Years

Home > Glass Tube Fuse >

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Aolittel Technology Co.,Ltd
Contact Now

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Brand Name : AOLITTEL

Model Number : TBP1500A

Certification : UR,C-UR,CQC,VDE,PSE

Place of Origin : CHINA

MOQ : 1000 Pieces

Price : Negotiable

Payment Terms : T/T

Supply Ability : 10,000,000 Pieces Per Month

Delivery Time : 7-10 Days

Packaging Details : Bulk,500pcs/bag,0.6g/pcs

Type : Glass Tube Fuse

Dimension : 4x11mm

Current Rating : 5A

Rated Voltage : 250VAC

Blow : Slow/Time Delay

Cap : Nickel Plated Brass

Body : Glass Tube

Fuse Element : Alloy

Lead Wire : Tin Plated Copper

Operating Temperature : -55℃~+125℃

Contact Now

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Shortcut info

Product name: glass fuse; rated Voltage: AC 250V; rated current: 5A
Function: slow blow; body Size: 11 x 4mm/ 0. 4' x 0. 15' (LED)
Wire Leads length(each): 27mm/ 1 inch
Color: Clear, Silver Tone; material: glass, alloy

___________________________________________________________Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag Download________

Specification

A=250V B=125V

Part

No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

TBP0250A 250mA 250V 240 0.06
TBP0315A 315mA 250V 220 0.09
TBP0400A 400mA 250V 200 0.2
TBP0500A 500mA 250V 190 0.4
TBP0630A 630mA 250V 180 1.0
TBP0800A 800mA 250V 160 1.9
TBP1100A 1A 250V 140 4.2
TBP1125A 1.25A 250V 130 8.7
TBP1160A 1.6A 250V 120 10.1
TBP1200A 2A 250V 100 20.3
TBP1250A 2.5A 250V 100 40
TBP1315A 3.15A 250V 100 68
TBP1400A 4A 250V 100 100
TBP1500A 5A 250V 100 133
TBP1630A 6.3A 250V 100 172

Certifications

Voltage Rating

Agency

Ampere Range

Agency File Number

250V UR 250mA ~ 5A E340427(JDYX)
C-UR 250mA ~ 5A E340427( JDYX7)
CQC 250mA ~ 5A CQC16012161227
VDE 500mA,1A,1.25A,1.6A,2A,2.5A,3.15A,5A 40032053
PSE 250mA ~ 5 A Pending
KTL 250mA ~ 5 A Pending

Standards:In accordance with IEC60127-1, IEC60127-3, GB9364.1, GB9364.3.

Dimension (mm)

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag
Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Operating Characteristics

% of Ampere Rating(In)

Blowing Time

210%*In 2 min Max
275%*In 400 ms~10 s
400%* In 150 ms~3s

Average Time Current Curves

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Installation Recommendations

Propose installation way as following picture.

A.Horizontal installation Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag
B.Vertical installation Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag
C.Vertical installation Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Checking and replacing fuses

Procedure

Many electrical devices used in eye care have an externally accessible fuse near the electrical cord (Figure 1) that you can check and replace by following these steps.

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Figure 1

  1. Disconnect the device from the electrical system.
  2. Remove the fuse from its holder. In some cases you may need a small screwdriver to unscrew the fuse holder cap.
  3. Look at the fuse wire. If there is a visible gap in the wire or a dark or metallic smear inside the glass then the fuse is blown and needs to be replaced. If you cannot see whether the fuse is blown, follow steps 4 and 5. If the fuse is definitely blown, go to step 6.
  4. Set a multimeter (Figure 2) to the resistance or Ω (Ohms) setting.

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Figure 2

5.Place one of the multimeter leads on one end of the fuse. Place the other lead on the other end of the fuse. If the reading is between 0 and 5 Ω (Ohms), the fuse is good. A higher reading indicates a bad or degraded fuse. A reading of OL (Over Limit) definitely means a blown fuse.

6.If the fuse is blown, replace the fuse with one that is exactly the same (see panel). Make sure to note the fuse amperage and voltage ratings, which should be marked on the fuse itself (Figure 3) or on the panel label near the fuse holder. Additionally, note the size and whether it is a slow-blow or a fast-blow type fuse. If there are no markings on the fuse itself or on the equipment you must consult the device's operating manual.

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Figure 3

General suggestions

*Always disconnect equipment from electrical power before removing a fuse; not doing so may result in serious injury.
*Always replace a fuse with an identical type, and never substitute a fuse with foil or another object. This could lead to electrocution and fires.
*Keep enough stock of the fuses used in your clinic or hospital. Store each type in separate containers with a label describing the fuse's voltage and amperage, whether it is a fast-blow or slow-blow type, the size, minimum number needed (the minimum stock level), and the models of equipment that use each type of fuse.
*Check your stock of fuses frequently and order more fuses when it reaches the minimum stock level.
If possible, tape a spare fuse to the equipment so that it is available when needed.


Product Tags:

small glass fuses

      

mini glass fuse

      
Quality Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag for sale

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Aolittel Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)